-40%
300A Industrial SSR Internal Work DCIndustrial ControlSolid State Relay For
$ 23.26
- Description
- Size Guide
Description
Feature:1. High Performance: Excellent power cycle capability and temperature characteristics, stable trigger current, better protection of electrical appliances, and higher isolation voltage.
2. Aluminum Base Plate: Good thermal conductivity, faster heat dissipation, service life, more safety and stability.
3. Material: Internally filled with epoxy resin, shock proof, moisture proof and corrosion proof.
4. Internal Work: The internal work method is adopted, no internal contact work is required, there is no mechanical contact, and the spark generation is rejected from the source.
5. Insulation Withstand Voltage: Photoelectric isolation between input and output circuits, insulation withstand voltage 2500V.
Specification:
Item Type: Industrial State Relay
Product Material: ABS, Aluminum
Model: H3300ZF
Control Mode: DC Control AC
Work Indication: LED
Ambient Temperature: -20℃~75℃
Installation Method: Bolted
Input: 4-32VDC
Output: 30-450VAC
Input Parameters:
Control Voltage Range: 3-32VDC
Minimum Control Current: 5mA
Maximum Control Current: 15mA
Make Sure To Turn On The Voltage: 3.5VDC
Ensure Shutdown Voltage: 1.5VDC
Output Parameters
Output Voltage Range: 24-480VAC
Maximum Load Current: 300A
Peak Voltage: 1200VAC
Insulation Resistance: 1000MΩ/500VDC
Leakage Current In Off State: ≤2mA Rms
Saturation Voltage Drop In On State: ≤1.5V
On Off Response Delay: ≤10ms
General Features:
Insulation Withstand Voltage Between Input And Output: 2500V Rms
Insulation Withstand Voltage Between Input And Output And Shell: 4000V Rms
Product Size: Approx.94 x 25 x 38.5mm / 3.7 x 1 x 1.5in
Package List:
1 x Industrial State Relay
Note:
1. When selecting relays, please pay special attention to the working current and ambient temperature of the load. When the load is working, it is necessary to add enough radiators or take other effective heat dissipation measures.
2. The heat generated by the relay needs to be dissipated through the metal base plate of the relay. When installing, please pay attention to the close cooperation between the relay and the heat sink. The installation should be firm and the joint should be coated with thermal grease.
3. When the connection between the output terminal and the load line is loose, the heat generated during power on will cause the product to burn. The following are the recommended screw installations for product wiring: M4 screw installation, the torsion is 0137‑1.7N m, M8 screw installation torsion is 1.77 ‑2.17N·m, excessive torsion will damage the relay.
4. Above 50A (including 50A) are enhanced state relays.
1. Our listing price includes the value of goods,packaging cost,and export
taxes,not including international duties.
2. duties,taxes,and charges are not included in the item price or shipping fee.
3.
T
he duties are buyers' responsibility
.Please check with your country's
customs office determine what these additional costs will be prior to your
purchase.
4. All disputes arising from the duties will be submitted to ebay for solution.
1. Any questions,
pls. contact us via ebay message or email us.
We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. post a message again because sometimes our message system may block some emails.
2. If you are satisfied with our service, pls. kindly leave us a positive feedback and give us the Detailed Seller Rating with all "
5
" in very area
3. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better.
We strive to keep all our customers satisfy.
We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.